{"product_id":"rondson-eva-3000m-master-control-unit-with-integrated-500-w-class-d-amplifier-up-to-8-supervised-loudspeaker-zones-full-fault-monitoring-en-54-16-compliance-built-in-audio-storage-scheduling-amplifier-redundancy","title":"Rondson EVA-3000M Master control unit with integrated 500 W Class‑D amplifier, up to 8 supervised loudspeaker zones, full fault monitoring, EN 54‑16 compliance, built‑in audio storage, scheduling, amplifier redundancy","description":"\u003ch3\u003e\u003cstrong\u003eCARATTERISTICHE\u003c\/strong\u003e\u003c\/h3\u003e\u003cp\u003eEVA‑3000M è l’unità di controllo principale del sistema di evacuazione vocale e diffusione sonora Honeywell INTEVIO, progettata per gestire, monitorare e coordinare tutti i dispositivi collegati. Funziona come cuore operativo dell’intero impianto, integrando funzioni avanzate come archiviazione e riproduzione audio, controllo delle zone, monitoraggio dei segnali, programmazione temporizzata e diagnosi automatica dei guasti.\u003c\/p\u003e\n\u003cp\u003eDispone di un amplificatore da 500 W integrato, in grado di pilotare fino a 8 linee di diffusori \/ altoparlanti, rendendolo ideale per applicazioni di piccole e medie dimensioni. Per installazioni più estese, può essere collegato a espansioni di zona per aumentare la capacità del sistema.\u003c\/p\u003e\n\u003cp\u003eIl sistema è completamente supervisionato e in grado di rilevare e segnalare anomalie relative ad alimentazione principale e di backup, CPU, microfoni, amplificatori, circuiti diffusori e contatti puliti, con registrazione dei log nella memoria interna. Anche in caso di malfunzionamento della CPU, l’unità consente comunque l’esecuzione di annunci di emergenza tramite microfono PTT, garantendo continuità operativa.\u003c\/p\u003e\n\u003cp\u003eL’EVA‑3000M integra inoltre funzioni come registrazione e riproduzione immediata dei messaggi, doppio canale audio per musica di sottofondo e annunci simultanei, gestione di amplificatori esterni e soluzioni di backup automatico che riducono i costi di sistema. La configurazione può essere effettuata tramite software dedicato o direttamente dal pannello LCD frontale.\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"color: rgb(22, 145, 121);\"\u003e\u003cstrong\u003eVantaggi per gli utenti\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli class=\"MsoNormal\"\u003eDiagnostica automatica con registrazione dei guasti e supervisione completa di alimentazioni, CPU, microfoni, amplificatori e linee di diffusori\u003c\/li\u003e\n\u003cli class=\"MsoNormal\"\u003eContinuità operativa garantita: gli annunci funzionano anche in caso di guasto della CPU\u003c\/li\u003e\n\u003cli class=\"MsoNormal\"\u003eAmplificatore in Classe-D da 500 W integrato con supporto fino a 8 zone, espandibile tramite moduli aggiuntivi\u003c\/li\u003e\n\u003cli class=\"MsoNormal\"\u003eRegistrazione e riproduzione immediata dei messaggi tramite microfono PTT o call station\u003c\/li\u003e\n\u003cli class=\"MsoNormal\"\u003eFunzioni Plug\u003cspan style=\"font-family: Cambria Math, serif;\"\u003e \u0026amp; \u003c\/span\u003ePlay, timer integrato, monitoraggio audio e interfaccia LCD intuitiva\u003c\/li\u003e\n\u003cli class=\"MsoNormal\"\u003eRiduzione dei costi grazie alla condivisione degli amplificatori e alla possibilità di utilizzare un solo amplificatore di backup per l’intero sistema\u003c\/li\u003e\n\u003cli class=\"MsoNormal\"\u003eCompatibilità con sistemi di terze parti, come impianti antincendio, tramite contatti puliti\u003c\/li\u003e\n\u003cli class=\"MsoNormal\"\u003eMemoria interna da 1 GB e SD card da 4 GB per file audio, configurazioni e log\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan style=\"color: rgb(35, 111, 161);\"\u003e\u003cstrong\u003eAmbiti di utilizzo\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli class=\"MsoNormal\"\u003eSistemi di evacuazione vocale certificati EN 54\u003cspan style=\"font-family: 'Cambria Math',serif; mso-bidi-font-family: 'Cambria Math';\"\u003e‑\u003c\/span\u003e16 in edifici singoli\u003c\/li\u003e\n\u003cli class=\"MsoNormal\"\u003eStrutture commerciali: centri commerciali, supermercati, negozi\u003c\/li\u003e\n\u003cli class=\"MsoNormal\"\u003eEdifici pubblici: scuole, uffici, biblioteche, municipi\u003c\/li\u003e\n\u003cli class=\"MsoNormal\"\u003eAmbienti industriali e logistici\u003c\/li\u003e\n\u003cli class=\"MsoNormal\"\u003eHotel, strutture ricettive e complessi multifunzionali\u003c\/li\u003e\n\u003cli class=\"MsoNormal\"\u003eImpianti che richiedono annunci programmati, musica di sottofondo e comunicazioni di emergenza\u003c\/li\u003e\n\u003cli class=\"MsoNormal\"\u003eInstallazioni che necessitano di supervisione continua e alta affidabilità operativa\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003e\u003cstrong\u003eSPECIFICHE\u003c\/strong\u003e\u003c\/h3\u003e\u003cul\u003e\n\u003cp\u003e\u003cspan style=\"background-color: rgb(255, 255, 255); color: rgb(0, 0, 0);\"\u003e\u003cstrong\u003eTechnical characteristics\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eMain power supply: 100 - 240 V\u003csub\u003eAC\u003c\/sub\u003e 50\/60 Hz\u003c\/li\u003e\n\u003cli\u003eBackup power supply: 21.5 - 28.5 V\u003csub\u003eDC\u003c\/sub\u003e\n\u003c\/li\u003e\n\u003cli\u003eFuse: T 10 AH 250 V\u003c\/li\u003e\n\u003cli\u003ePower consumption: \u0026lt; 740 W\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003ePTT microphone\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eSensitivity: -59 ±3 dBV\u003c\/li\u003e\n\u003cli\u003eFrequency response: 100 Hz - 14 kHz ±3 dB\u003c\/li\u003e\n\u003cli\u003eSNR: \u0026gt; 50 dB, A-weighted\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eAuxiliary input\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eNumber: 2\u003c\/li\u003e\n\u003cli\u003eInput sensitivity: 1 V (0 dBV)\u003c\/li\u003e\n\u003cli\u003eInput impedance: 10 kohm\u003c\/li\u003e\n\u003cli\u003eFrequency response: 85 Hz - 18 kHz ±3 dB\u003c\/li\u003e\n\u003cli\u003eSNR: \u0026gt; 80 dB, A-weighted\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eMIC \/ line input\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eInput sensitivity: 5 mV \/ 1 V, set by DIP switch\u003c\/li\u003e\n\u003cli\u003eInput impedance: 20 kohm\u003c\/li\u003e\n\u003cli\u003eFrequency response: 80 Hz - 18 kHz, ±3 dB\u003c\/li\u003e\n\u003cli\u003eSNR: \u0026gt; 80 dB, A-weighted\u003c\/li\u003e\n\u003cli\u003ePhantom power output: 24 V\u003csub\u003eDC\u003c\/sub\u003e, set by DIP switch\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eAudio output\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eOutput channels: CH1, CH2 and record\u003c\/li\u003e\n\u003cli\u003eOutput signal: 1 V (0 dBV)\u003c\/li\u003e\n\u003cli\u003eTHD: \u0026lt; 0.1%\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eInternal power amplifier\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eMax. power output: 500 W\u003c\/li\u003e\n\u003cli\u003eOutput signal: 100 V (CH1A)\u003c\/li\u003e\n\u003cli\u003eFrequency response: 80 Hz - 18 kHz ±3 dB\u003c\/li\u003e\n\u003cli\u003eTHD: \u0026lt; 0.1%\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003ePower amplifier interface\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eNumber: 3 (CH1, CH2 and spare amplifier)\u003c\/li\u003e\n\u003cli\u003eOutput signal: 1.4 V\u003c\/li\u003e\n\u003cli\u003eTHD: \u0026lt; 0.1%\u003c\/li\u003e\n\u003cli\u003eControl signal: self-testing, amplifier fault and power saving control signal\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eLoudspeaker interface\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eZone number: 8 (each has A and B output)\u003c\/li\u003e\n\u003cli\u003eMax. load power: 500 W\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eContact IN\/OUT\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eContact input: 10 contact input interfaces with supervision\u003c\/li\u003e\n\u003cli\u003eContact output: 8 contact output interfaces (NO, NC and COM), “Fault” output and “Alarm” output\u003c\/li\u003e\n\u003cli\u003eMax. voltage of the outputs: 250 V\u003csub\u003eAC\u003c\/sub\u003e 30 V\u003csub\u003eDC\u003c\/sub\u003e\n\u003c\/li\u003e\n\u003cli\u003eMax. current of the outputs: 2.5 A\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eOthers\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eDC power output: 24 V \/ 1 A\u003c\/li\u003e\n\u003cli\u003eMonitoring loudspeaker: 2 W \/ 8 ohm\u003c\/li\u003e\n\u003cli\u003eEthernet interface: 10M \/ 100M\u003c\/li\u003e\n\u003cli\u003eMemory capacity: 1 GB flash memory, 4 GB SD card\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eWorking conditions\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eRelative humidity: \u0026lt; 95%, without condensing\u003c\/li\u003e\n\u003cli\u003eOperating temperature: -10 to 50 °C  \u003c\/li\u003e\n\u003cli\u003eStorage temperature: -40 to 70 °C  \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eDimensions (W x H x D): 48.2 x 13.35 x 42 cm\u003c\/li\u003e\n\u003cli\u003eWeight: 14.3 kg\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e","brand":"Rondson","offers":[{"title":"Default Title","offer_id":54311711342925,"sku":"02943","price":5068.03,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0972\/0643\/6173\/files\/41247_02943_big.jpg?v=1784201865","url":"https:\/\/musicdelivery.net\/es\/products\/rondson-eva-3000m-master-control-unit-with-integrated-500-w-class-d-amplifier-up-to-8-supervised-loudspeaker-zones-full-fault-monitoring-en-54-16-compliance-built-in-audio-storage-scheduling-amplifier-redundancy","provider":"Music Delivery","version":"1.0","type":"link"}